MTSA Power2Power Systeem 6 MW
Main Technology: PEM Safety: CE mark Electrolyser section Hydrogen purity: ISO 14687 / NEN-EN 17124 Hydrogen production: up to 114 kg/hr Electricity consumption: up to 6 MW Hydrogen Compressor / Storage section Storage Capacity: 1250 kg Max pressure: 500 bar Fuel cell section Electricity production: up to 2 MWe output at 10 kV/AC Hydrogen consumption: […]Lees verder »
MTSA Power2Power Systeem 0,5 MW
Main Technology: PEM Safety: CE mark Electrolyser section Hydrogen purity: ISO 14687 / NEN-EN 17124 Hydrogen production: Up to 9 kg/hr Electricity consumption: up to 500 kW Hydrogen Compressor / Storage section Storage Capacity: 97 kg Max pressure: 500 bar Fuel cell section Electricity production: up to 150 kWe output at 10 kV/AC Hydrogen consumption: […]Lees verder »
MTSA 2 MW Brandstofcel Systeem
Main Technology: PEM Electricity production: up to 2 MWe output at 10 kV/AC Residual heat production: up to 1.4 MW at 60 deg. C Hydrogen consumption: max 125 kg/hr Safety: CE markLees verder »
MTSA 1 MW Brandstofcel Systeem
Main Technology: PEM Electricity production: up to 1 MWe output at 10 kV/AC Residual heat production: up to 700 kW at 60 deg. C Hydrogen consumption: max 63 kg/hr Safety: CE markLees verder »
MTSA 2 MW elektrolyser module
Main Technology: PEM Hydrogen production: up to 38 kg/hr Hydrogen purity: ISO 14687 / NEN-EN 17124 Output pressure: Up to 40 bar Safety: CE mark Max Input power: 2 MWe Feed water quality: Tap waterLees verder »
MTSA 1 MW elektrolyser module
Main Technology: PEM Hydrogen production: up to 19 kg/hr Hydrogen purity: ISO 14687 / NEN-EN 17124 Output pressure: Up to 40 bar Safety: CE mark Max Input power: 1 MWe Feed water quality: Tap waterLees verder »
MTSA 50 kW elektrolyser
Main Technology: PEM Hydrogen production: up to 0,9 kg/hr Hydrogen purity: ISO 14687 / NEN-EN 17124 Output pressure: Up to 40 bar Safety: CE mark Max Input power: 50 kWe Feed water quality: Tap waterLees verder »
Disconnectors and Earthing Switches
MTSA Disconnector 1608 Max. voltage: 36 kV Max. current (rms, 1s): 110 kA Peak current: 308 kALees verder »
Re-Ignition Spark Gap 1606
Air gap: Two half spheres, variable gap 5 – 25 cm Dielectric stability (Umax): 250 kV ± 15 kV Current (Imax): 80 kApeak /5 ms Maximum Charge transfe: 200 C Response time: < 5 ms Lees verder »
Main Gap 800 kV
Air gap: Two half spheres, variable gap 10 – 80 cm Rated DC voltage: up to 800 kV Peak current: 40k A, damped, frequency 50 Hz to 3000 Hz Response time:Lees verder »
test
testLees verder »
Rogowski Measuring Set
Sensitivity: from 0.5 kA/V to 50 kA/V Current range: currents up to a maximum of 1 mega ampere Frequency range: LF to 0.007 Hz Accuracy: better than 1% Phase error: better than 20 minutes of an arc at 50 HzLees verder »
Re-ignition Stack
Input: Light: 860 nm Minimum optical capacity: 50 mW SMA-connector. Rise time < 0.5 μs Delay: < 1,5 μs Timing accuracy < 0,5 μs Voltage: 10 kV tot 25kV per section Maximum charge transfer: 0,5 C per injection Maximum current: 5000 ALees verder »
High Energy Gap Firing Unit
Power supply: Compressed air – 6 bar Control unit: via fiber-optic high level input (>30 mWatt) Ignition pulse maximum voltage: 25 kVolt Elec. energy of 1st ignition pulse: approx. 0.25 Joule/25 kVolt Elec. energy of 2nd ignition pulse: approx. 200 Joule/850 Volt Response time: < 5 micro secondsLees verder »
Main Gap
Maximum voltage: 820 kV Two High Energy Gap Firing Units Timing via Injection TimerLees verder »
Synthetic Make Switch
Rated voltage: 250kV Rated current: 80 kAeff/5 msLees verder »
Test System For Injection Timer
For checking condition of Injection Timer Simulates current forms which appear during a short circuit testerLees verder »
Injection Timer
Injection Timer is used in synthetic test circuit Injection Timer predicts when AC current goes through zero Injection Timer emits ignition commands to main gap Injection Timer emits signals to control multi loop devicesLees verder »
Master Break Switch
Rated opening time: <7 ms Deviation in breaking time: <0,2 ms Rated voltage: 15.4 kV at 50 Hz & 160 kA Max. breaking test current: 165 kALees verder »
Make Switch 1397
Rated voltage: 36 kV Making current (symmetric): 80 kA Closing time* < 8 ms Precision of make-time: < 0.1 msLees verder »
Make Switch 1210
Rated voltage: 24 kV Making current (symmetric): 100 kA Closing time* < 8 ms Precision of make-time: < 0.1 msLees verder »





















