MTSA Power2Power System 6 MW

Main Technology: PEM Safety: CE mark Electrolyser section Hydrogen purity: ISO 14687 / NEN-EN 17124 Hydrogen production: up to 114 kg/hr Electricity consumption: up to 6 MW Hydrogen Compressor / Storage section Storage Capacity: 1250 kg Max pressure: 500 bar Fuel cell section Electricity production: up to 2 MWe output at 10 kV/AC Hydrogen consumption: […]Read more »

Power to Power

MTSA Power2Power System 0,5 MW

Main Technology: PEM Safety: CE mark Electrolyser section Hydrogen purity: ISO 14687 / NEN-EN 17124 Hydrogen production: Up to 9 kg/hr Electricity consumption: up to 500 kW Hydrogen Compressor / Storage section Storage Capacity: 97 kg Max pressure: 500 bar Fuel cell section Electricity production: up to 150 kWe output at 10 kV/AC Hydrogen consumption: […]Read more »

Fuel Cell System

MTSA 2 MW Fuel Cell System

Main Technology: PEM Electricity production: up to 2 MWe output at 10 kV/AC Residual heat production: up to 1.4 MW at 60 deg. C Hydrogen consumption: max 125 kg/hr Safety: CE markRead more »

Fuel Cell System

MTSA 1 MW Fuel Cell System

Main Technology: PEM Electricity production: up to 1 MWe output at 10 kV/AC Residual heat production: up to 700 kW at 60 deg. C Hydrogen consumption: max 63 kg/hr Safety: CE markRead more »

Electrolyser

MTSA 2 MW Electrolyser Module

Main Technology: PEM Hydrogen production: up to 38 kg/hr Hydrogen purity: ISO 14687 / NEN-EN 17124 Output pressure: Up to 40 bar Safety: CE mark Max Input power: 2 MWe Feed water quality: Tap waterRead more »

Electrolyser

MTSA 1 MW Electrolyser Module

Main Technology: PEM Hydrogen production: up to 19 kg/hr Hydrogen purity: ISO 14687 / NEN-EN 17124 Output pressure: Up to 40 bar Safety: CE mark Max Input power: 1 MWe Feed water quality: Tap waterRead more »

Electrolyser

MTSA 50 kW Electrolyser

Main Technology: PEM Hydrogen production: up to 0,9 kg/hr Hydrogen purity: ISO 14687 / NEN-EN 17124 Output pressure: Up to 40 bar Safety: CE mark Max Input power: 50 kWe Feed water quality: Tap waterRead more »

Disconnectors and Earthing Switches

Disconnectors and Earthing Switches

MTSA Disconnector 1608 Max. voltage: 36 kV Max. current (rms, 1s): 110 kA Peak current: 308 kARead more »

Re-Ignition-Spark-Gap 2

Re-Ignition Spark Gap 1606

Air gap: Two half spheres, variable gap 5 – 25 cm Dielectric stability (Umax): 250 kV ± 15 kV Current (Imax): 80 kApeak /5 ms Maximum Charge transfe: 200 C Response time: < 5 ms Read more »

Main Gap 800 kV

Air gap: Two half spheres, variable gap 10 – 80 cm Rated DC voltage: up to 800 kV Peak current: 40k A, damped, frequency 50 Hz to 3000 Hz Response time:Read more »

Rogowski Measuring Set

Sensitivity: from 0.5 kA/V to 50 kA/V Current range: currents up to a maximum of 1 mega ampere Frequency range: LF to 0.007 Hz Accuracy: better than 1% Phase error: better than 20 minutes of an arc at 50 HzRead more »

Re-ignition Stack

Input: Light: 860 nm Minimum optical capacity: 50 mW SMA-connector. Rise time < 0.5 μs Delay: < 1,5 μs Timing accuracy < 0,5 μs Voltage: 10 kV tot 25kV per section Maximum charge transfer: 0,5 C per injection Maximum current: 5000 ARead more »

High Energy Gap Firing Unit

Power supply: Compressed air – 6 bar Control unit: via fiber-optic high level input (>30 mWatt) Ignition pulse maximum voltage: 25 kVolt Elec. energy of 1st ignition pulse: approx. 0.25 Joule/25 kVolt Elec. energy of 2nd ignition pulse: approx. 200 Joule/850 Volt Response time: < 5 micro secondsRead more »

Main Gap

Maximum voltage: 820 kV Two High Energy Gap Firing Units Timing via Injection TimerRead more »

Synthetic Make Switch

Rated voltage: 250kV Rated current: 80 kAeff/5 msRead more »

Test System For Injection Timer

For checking condition of Injection Timer Simulates current forms which appear during a short circuit testerRead more »

Injection Timer

Injection Timer is used in synthetic test circuit Injection Timer predicts when AC current goes through zero Injection Timer emits ignition commands to main gap Injection Timer emits signals to control multi loop devicesRead more »

Master Break Switch

Rated opening time: <7 ms Deviation in breaking time: <0,2 ms Rated voltage: 15.4 kV at 50 Hz & 160 kA Max. breaking test current: 165 kARead more »

Make Switch 1397

Make Switch 1397

Rated voltage: 36 kV Making current (symmetric): 80 kA Closing time* < 8 ms Precision of make-time: < 0.1 msRead more »

Make Switch 1210

Make Switch 1210

Rated voltage: 24 kV Making current (symmetric): 100 kA Closing time* < 8 ms Precision of make-time: < 0.1 msRead more »